Pseudonyms
Gluc, Blood Sugar; RBG, RBS, FBG, FBS
Collection Requirements
4 ml Fluoride Oxalate, Lithium Heparin or Serum
Tube Colour
Grey, Light Green, Gold
Test image(s)
Requires own tube?
No
Department
BiochemistryReference Interval
Non-fasting 3.3 - 7.7 mmol/L
Fasting 3.3 - 6.0 mmol/L
A fasting glucose >6.9 mmol/L or random glucose >11.0 mmol/L is seen with Diabetes mellitus. Note: if not known to be a diabetic, confirmation of diagnosis may be required.
Availability
Daily
Fee
Medicare rebatable Item No. 66500
Notes
Glucose collected in a lithium heparin or serum tube can result in falsely low result if there was a delay in separation. If there is clinical concern, please recollect in a fluoride oxalate tube.
Test code: G